  • WSSP-481 万向型一体化双金属温度计.jpg
  • WSSP2-481 一体化双金属温度计带pt100热电阻双支.jpg
  • WSSP-401 订制一体化双金属温度计轴向.jpg
  • WSSE-411 一体化双金属温度计带E分度号热电偶.jpg
  • WSSP-411 全不锈钢一体化双金属温度计带pt100热电阻.jpg
  • WSSE2-411 一体化双金属温度计带双支热电偶.jpg

WSSP-401 WSSP-411 WSSP-481 all stainless steel integrated bimetal thermometer with pt100 thermal resistance

Classification:

Bimetal thermometer

Key words:

Product Summary:

It is a kind of field detection instrument for measuring medium and low temperature. It can directly measure the temperature of liquid, steam and gas in the range of -80 ℃ ~ 500 ℃ in various production processes, and can be displayed on site or transmitted signals.

Tel: 15123315409

Return to List

Inquiry

Product Description

Application
WSSP-401 WSSP-411 WSSP-481 all stainless steel integrated bimetal thermometer with pt100 thermal resistance
It is a field measuring instrument for low temperature measurement. It can directly measure the temperature of liquid, steam and gas in the range of -80 ℃ ~ 500 ℃ in a variety of production process, can be displayed on the spot, can also be remotely transmitted signal.

Features
1. On-site display temperature, intuitive and convenient;
2. Safe and reliable, long service life;
3. Various structural forms can meet different requirements;
4. Remote signal 4-20mA



Working principle
Bimetallic thermometers are based on the composition of a bimetallic strip wound into a toroidal curvature. When one end is heated and expanded, the pointer is driven to rotate, and the working instrument shows the corresponding temperature value.
Thermal resistance is designed and manufactured by using the basic principle that the resistance value of platinum wire changes with the change of temperature. According to the resistance value R(℃) at 0 ℃, it is divided into 10 ohms (index number Pt10) and 100 ohms (index number Pt100), etc. The temperature measurement range is large and is suitable for -200~850 ℃.

Main technical parameters
1. Product implementation standard JB/T8803-1998
B. Nominal diameter: 60,100,1503. Accuracy class:(1.0),1.5
4. Thermal response time: ≤ 40s5. Protection class: IP55
6. Angle adjustment error: Angle adjustment error should not exceed 1.0% of its range
7. Return difference: the return difference of the thermometer should not be greater than the absolute value of the basic error limit.
8. Repeatability: The repeatability limit range of the thermometer should not be greater than 1/2 of the absolute value of the basic error limit.





 

Model   Dial diameter Connection form Process   interpretation
WSS           Bimetal thermometer
  P         With pt100 thermal resistance
    -3       Φ60mm dial diameter
    -4       Φ100mm dial diameter
    -25       Φ125mm dial diameter
    -5       Φ150mm dial diameter
      0     Axial, vertical connection
      1     Radial, bottom connection
      8     Universal type, adjustable angle
        0   No fixed installation method
        1   Movable external thread
        2   Movable internal thread
        3   Fixed external thread
        4   Fixed flange
        5   movable flange
        6   ferment flange
          C Protective type
          W protective tube
          F Anti-corrosion SS316
          F4 PTFE antiseptic