TGS55 WIKA All Stainless Steel Contact Bimetal Thermometer
Classification:
Bimetal thermometer
Key words:
Product Summary:
Product Description
The TGS55 bimetal thermometer with electrical contacts can be used for all applications where the process temperature needs to be displayed on site and the circuit must be switched. The electric contact switch (also called "alarm electric contact") can turn on or off the circuit according to the position of the pointer of the measuring instrument. The electrical contact switch is adjustable in the full range. The meter pointer (actual value pointer) can rotate freely within the entire range and is not affected by the setting. The setting pointer can be calibrated from the instrument window using a pluggable key (mounted on the terminal box). The electric contact switch not only contains a plurality of electric contacts, but also can set a single setting value. When the actual value pointer exceeds or falls below the set value, the electrical contacts will switch. The electrical contact switch includes an inductive electrical contact and an electronic electrical contact. The inductive contacts can be used in hazardous areas. Electronic contacts can be used to switch programmable logic controllers (PLC).
Functional characteristics
High reliability and long service life
General Application
Housing and probe made of stainless steel
Instruments with inductive contacts for use in hazardous areas
Electrical contact meter for PLC applications
| Rated power VA | Operating voltage | Bimetal thermometer | ||||
| 10 | 220VDC | 0.7A | ||||
| 24VAC | ||||||
Selection parameters
| WSS | Bimetal thermometer | ||||||
| X | Electric contact | ||||||
| Dial diameter | -4 | Φ100 | |||||
| Dial connection form | 0 | Axial (straight) | |||||
| 1 | Radial (angular) | ||||||
| 8 | Universal (adjustable angle type) | ||||||
| Process Connection | 0 | No fixed thread | |||||
| 1 | movable external thread | ||||||
| 2 | Movable internal thread | ||||||
| 3 | Fixed thread | ||||||
| 4 | Fixed flange | ||||||
| 5 | Thread of ferrule | ||||||
| 6 | ferrule flange | ||||||
| Electric contact form | M | upper and lower limits | |||||
| N | double upper limit | ||||||
| P | Double Lower Limit | ||||||
Example model:
| Model | Temperature range | Accuracy | Material of protection tube | Length | Process Connection | |
| WSSX-400 | -80~ 40 -40~ 80 0~50 0~100 0~150 0 to 200 0~300 0~400 0~500 |
1.5 | 1Cr18Ni9Ti 304 316 316L Hastelloy C- 276 |
75 100 150 200 300 400 500 750 1000 |
No fixed installation mode | |
| WSSX-401 | ||||||
| WSSX-480 | ||||||
| WSSX-401 | movable external thread | |||||
| WSSX-411 | ||||||
| WSSX-481 | ||||||
| WSSX-402 | Movable internal thread | |||||
| WSSX-412 | ||||||
| WSSX-482 | ||||||
| WSSX-403 | Fixed thread | |||||
| WSSX-413 | ||||||
| WSSX-483 | ||||||
| WSSX-404 | Fixed flange | |||||
| WSSX-414 | ||||||
| WSSX-484 | ||||||
| WSSX-405 | Thread of ferrule | |||||
| WSSX-415 | ||||||
| WSSX-485 | ||||||
| WSSX-406 | ferrule flange | |||||
| WSSX-416 | ||||||
| WSSX-486 | ||||||